HomeMy WebLinkAbout17621 W Country Club Dr_BLD1843_2025 i
E
CITY OF ARLINGTON
238 N. OLYMPIC AVE-ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING_ PERMIT
Address:17621 W Country Club Drive Permit#: 1943
Parcel#:00816000004700 Valuation:0.00
OWNER ,APPLICANT CONTRACTOR
Name:BRAULIO CARLOS&KARI Name:Brennan Heating Name:Brennan Heating
Address; 17621 W COUNTRY CLUB DR Address:4601 S 134th Place Address:4601 S 134th Place
City,Slate Zip:ARLINGTON,WA 98223-4650 City,Slate'Zip:Seattle,WA 98168 City,Slate Zip:Sealtle,WA 98168
Phone: Phone:106-248-7900 Phone:206-248-7900
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:Brennan Heating Name:
Address:4601 S 1341h Place Address:
City,Stale,Zip:Seattle,WA 98168 City,Slate,Zip:
Phone:206-248-7900 Phone:
LAC#:BRENNHA97IR9 EXP: 1 212 9/2 0 1 9 L.IC#:
JOB,DESCRIPTION r
PERMI r TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: 2 CONS'1,TYPE: `1B
DWELLING UNITS: j OCC GROUP: R3
BUILDINGS; OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPI.Y WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTIIORIZE•D
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LA13OR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.2T
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HAS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USI:OR OCCUPY A BUILDING OR ST'RUCPURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC]10/IRCI 10,
SAUISTAX NOT110Et Seles tax relating to construction and construction materials in the City of Arlil t T
on your sales tax return Iorm
an < d i f�l gton#3101.
14
wit7I11
Signature Print Name Date elemed By Dale
CONDITIONS
Approved as submitted. Adhere to the installation of furnace model #EL280DF09OP48B AFUE 80%and
A/C unit model #EL16XC1-048 SEER 16. Additional requirements: 3" concrete pad with seismic bracing
attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not
permitted.
l THIS PERMIT AUTHORIZS ONLY IT1E WORK NOTED.'MIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY
I CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATH PERMISSION
PERMIT FEES
Date Description Fee Amount
3/2/2018 Furnace $25.00
3/2/2018 Mechanical Permit Base Fee $25.00
3/2/2018 Processing/Technology Fee $25.00
Total Due: 575,00
Total Payment: $0 00
Balance Due: $75.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360)403-3551
BUILDING PERMIT
Address:17621 W Country Club Drive Permit#: 1843
Parcel#:00816000004700 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:BRAULIO CARLOS&KARI Name:Brennan Heating Name:Brennan Heating
Address: 17621 W COUNTRY CLUB DR Address:4601 S 134th Place Address:4601 S 134th Place
City,State Zip:ARLINGTON,WA 98223-4650 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168
Phone: Phone:206-248-7900 Phone:206-248-7900
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:Brennan Heating Name:
Address:4601 S 134th Place Address:
City,State,Zip:Seattle,WA 98168 City,State,Zip:
Phone:206-248-7900 Phone:
LIC#:BRENNHA97I R9 EXP: 12/29/2019 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: 2 CONST.TYPE: ` 13
DWELLING UNITS: 1 OCC GROUP: R3
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of ANl'
I e rt on your sales tax return form
and coded City of Arlington#3101.
Signature Print Name Date eased By Date
CONDITIONS
Approved as submitted. Adhere to the installation of furnace model #EL280DF09OP48B AFUE 80%and
A/C unit model #ELI6XC1-048 SEER 16. Additional requirements: 3" concrete pad with seismic bracing
attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not
permitted.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION
PERMIT FEES
Date Description Fee Amount
3/2/2018 Furnace $25.00
3/2/2018 Mechanical Permit Base Fee $25.00
3/2/2018 Processing/Technology Fee $25 00
Total Due: $75.00
Total Payment: $0 00
Balance Due: $75.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit Information
Date 3/2/2018
Permit Number 1843
Project Name Braulio
Applicant Name Brennan Heating
Applicant Address 4601 S 134th Place
City,State,Zip Seattle,WA 98168
Contact Jaimie How
Phone 206-248-7900
Email jaimie@brennanheating.com
Permit Type Residential Mechanical
Site Address 17621 W Country Club Drive
Valuation 0.00
Status Applied
Permit Issued
Permit Expires
Square Feet 0
Type of Construction/Occupancy Load
Number of Stories 0
Proposed Use Replace Gas Furnace and add A/C
Assigned To Kristin Foster
Property
Owner
Parcel Address Legal Owner Phone Zoning
00816000004700 17621 W COUNTRY CLUB BRAULIO CARLOS& 111 Single Family Residence-
DR KARI Detached
Contractors
Contractor Primary Phone Email Contractor Type License License#
Name Contact
Brennan 206-248 (MECHANICAL Labor and
Heatinglaimie How 7900 aimie@brennanheating.com,CONTRACTOR Industries 13RENNHA971 R
Fees
Fee Description Notes Amount
Furnace 322.10.00.00 $25.00
Mechanical Permit Base Fee 322.10.00.00 $25.00
Processing/Technology Fee 341.43.00.02 $25.00
Total $75.00
Notes
Date Note
3/2/2018 Furnace model#EL280DF090P48B AFUE 80%A/C model#EL16XC1-048 SEER 16
Uploaded Files I Upload File
Date File Uploaded By
3/2/2018 6 58 10 AM 11843 Apphcahon and Specs,r)dt Foster. Kristin I x
3/2/2018 BRENNAN HEATING&A/C LLC
Search L&I
Washington State Department of
" Labor & Industries
BRENNAN HEATING &A/C LLC
Owner or tradesperson 4601 S 134TH PL
SEATTLE,WA 98168
Principals 206-248-7900
ERDAHL,DARRIN PAUL,PARTNER/MEMBER KING County
Doing business as
BRENNAN HEATING&A/C LLC
WA UBI No. Business type
602 346 866 Limited Liability Company
Governing persons
DARRIN
P.
ERDAHL
ERIC L BEARDEMPHL;
JAMES JOLLY;
STEFANIE ERDAHL;
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
BRENNHA971R9
Effective—expiration
12/29/2003-12/2912019
Bond
FEDERATED MUTUAL INS CO $12,000.00
Bond account no.
9127230
Received by L&I Effective date
11/04/2004 12/22/2004
Expiration date
Until Canceled
Insurance
Federated Mutual Ins Co $1,000,000.00
Policy no.
9820726
Received by L&I Effective date
06/06/2017 07/13/2015
Expiration date
07/13/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
https://secure.ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA97l R9&SAW= 1/3
3/2/2018 BRENNAN HEATING&A/C LLC
No lawsuits against the bond or savings accou 'luring the previous 6 year period. 1
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
Infraction no.
PDOVE00515 Satisfied
Issue date RCW/WAC
01/26/2018 18.106.020
Violation city Violation amount
SEATTLE $250.00
Type of violation
PLUMBER INFRACTION
Description
Contractor employed a person to engage in
the trade of plumbing without a current
journeyman,specialty or trainee certificate,
temporary permit or medical gas endorsement
as required.
Infraction no.
PPEJP00330 Satisfied
Issue date RCW/WAC
09/14/2012 18.106.020
Violation city Violation amount
Seattle $250.00
Type of violation
PLUMBER INFRACTION
Description
Contractor employed a person to engage in
the trade of plumbing without a current
journeyman,specialty or trainee certificate,
temporary permit or medical gas endorsement
as required.On 9/11/12,Brennan Heating&
A/C LLC employed Levy Malcom Steere to
perform plumbing related duties without
proper plumbing certification.
Workers' comp
Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums.
L&I Account ID Account is current.
803,761-08
Doing business as
BRENNAN HEATING&AIR CONDIT
Estimated workers reported
Quarter 4 of Year 2017"Greater than 100 Workers"
L&I account contact
T4/NIKKI BUTLER(360)902-4918-Email:BUT0235@lni.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
hfps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA971 R9&SAW= 2/3
3/2/2018 BRENNAN HEATING&A/C LLC
NJashinglon State Dept of Labor&Industries.Use of+his site is subject to the laws or`the skate of Washington,
https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA971 R9&SAW= 3/3
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL
INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL
PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION,
Project Address: 1PI'2 (_(�l� oy )a_6`/ C y h_ ___ iC _ —LL.YS-� ► L-.
c
Project Description: �l—.l�) _ (Z y� ��
Owner: LA �� _ ICE-r I `f rA t) i 0 --- - —
Address: -
Phone: �JF5 �-�'D rj'� Imo_ - Email: - -
Applicant: Brennan Heating
Address: 4601 S 134th PI Seattle 98168
Phone: 206-248-7900 Email: Jaimie@brennanheating.com
Applicant Signature: -
61
Electronic Signature if submitting on-line
1 hereby certify that the above information is correct and that the construction, installation for the
above mentioned property will be in accordance with the applicable laws of the City of Arlington
and the State of Washington.
CONTRACTOR INFORMATION
Contractor Name Brennan Heating
Company: Brennan Heating
License Number:BRENNHA971 R9 Expiration:12129 C)11
Phone:206-248-7900 Email:Jaimie@brennanheating.com
STAFF USE ONL Received
Permit #: I�' Accepted by: _
Date: - crD 95 2nTaT
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ
❑ Heat Pump Freestanding Stove ❑ Hydronic Piping
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System
❑ Boiler ❑ Gas Piping ❑ Storage Tank
AC Unit ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable:
Pipe Material:
Pipe Size:
Distance From Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
CAR..os 1. µpiL-%
X-c 6-L% w c.00.n�'+
L vri ov,
T
y' Ipac.K ?M?Ot'l
I
I
GAaa6i� 30' .i
A-
Couh,fi•( C..�JCS D1� .
SPECIFICATIONS
General Model No. All Regions EL16XC1-041 EL16XC1-042 EL16XCl-047 EL16XCl-048 EL16XC1-060
Data Nominal Tonnage 3.5 3.5 4 4 5
Connections Liquid line(o.d.)-in. 318 3/8 3/8 3/8 3/8
(sweat) Suction line(o.d.)-in. 7/8 718 7/8 7/8 1-1/8
Refrigerant R-410A charge furnished 9 lbs.9 oz. 8 lbs. 12 oz. 11 lbs.0 oz. 9 lbs. 12 oz. 12 lbs.0 oz.
Outdoor Net face area-sq.ft. Outer coil 21.00 1 21.00 22.17 21.00 29.09
Coil Inner coil 20.25 20.25 21.33 20.25 28.16
Tube diameter-in. 5116 5/16 5116 5/16 5/16
No.of rows 2 2 2 2 2
Fins per inch 22 22 22 22 22
Outdoor Diameter-in. 22 22 26 22 26
Fan No,of blades 3 3 4 4 3
Motor hp 1/6 1/6 1/3 /. 113
Cfm 3050 3050 4400 3600 4550
Rpm 825 825 825 825 825
Watts 190 190 310 310 310
Shipping Data-lbs.1 pkg, 227 234 272 255 284
ELECTRICAL DATA
Line voltage data-60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph
'Maximum overcurrent protection(amps) 30 40 35 40 50
'Minimum circuit ampacity 19.3 23.4 21,9 24.2 29.6
Compressor Rated load amps 14.7 17.9 16A 18.0 22.2
Locked rotor amps 75 112 105.5 117 127.9
Power factor 0.96 0.96 0.98 0.96 0.98
Outdoor Fan Motor Full load amps 1 1 1.8 1.7 1.8
Locked rotor amps 1.9 1.9 2.9 3.2 2.9
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater 93M04
93M06
Factory
Compressor Hard Copeland 1 OJ42
Start Kit LG 88M91
Compressor Low Ambient Cut-Off Switch 45F08
Compressor Timed-Off Control 47,135
Freezestat 3/8 in.tubing 93G35
5/8 in.tubing 5OA93
Indoor Blower Off Delay Relay 58M81
Loss of Charge Switch Kit 84M23
'Low Ambient Kit(Fan Cycling) 34M72
Refrigerant L15-65-30 L15-65-40
Line Sets L15-65-50
Field Fabricate
NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage.
Refrigerant charge sufficient for 1s n.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set length and
addlilonal refrigerant charge required.
HACR type breaker or fuse.
Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements.
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
EL16XC1 -1.5 to 5 Ton Air Conditioner 1 Page 7
SPECIFICATIONS
Gas Model No. EL28ODF07OP36A EL28ODF09OP48B EL28ODF11OP60C
Heating Performance 1 AFUE 80% 80% 80%
High Input-Btuh 66,000 88,000 110,000
Fire
Output-Btuh 52,000 69,000 87,000
Temperature rise range-°F 30-60 35-65 40-70
Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5 1 10.0
Nat.Gas/LPG/Propane
Low Input-Btuh 43,000 57,000 72,000
Fire Output-Btuh 35,000 46,000 59,000
Temperature rise range-°F 20-50 20-50 25-55
Gas Manifold Pressure(in,w.g.) 1.7/4.9 1.7/4.9 1.7/4.9
Nat.Gas/LPG/Propane
High static-in.w.g. Heating 0.5 0.5 0.5
Cooling 0.5 0.5 0.5
Connections Flue connection-in.round 4 4 4
in.
Gas pipe size IPS 1/2 1/2 1/2
Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 10 11-1/2 x 10
Blower
Motor output-hp 1/3 1/2 1
Tons of add-on cooling 2-3.5 3-4 4-5
Air Volume Range-cfm 717-1562 917-1929 1517-2760
Electrical Voltage 120 volts-60 hertz-1 phase
Data
Blower motor full load amps 6.1 8.2 11.5
Maximum overcurrent protection 15 15 15
Shipping Data lbs.- 1 package 128 140 160
NOTE-Filters and provisions for mounting are not furnished and must be field provided.
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating For non-weatherized
furnaces.
OPT16NAL ACCESSORIES-ORDER SEPARATELY
"A"Width "B"Width I "C"Width
Models Models Models
CABINET ACCESSORIES
Downflow Combustible Flooring Base I 11 M59 11 M60 I 11 M61
DOWNFLOW FILTER KITS
Downflow Filter Kit 51W06 51W07 51W08
No. and Size of filter-in. (1)20 x 20 x 1 (2)16 x 20 x 1 (2)16 x 20 x 1
NIGHT SERVICE KIT
Night Service Kit I 84W46 I 84W46 I 84W46
EL28ODF/Page 5