Loading...
HomeMy WebLinkAbout17621 W Country Club Dr_BLD1843_2025 i E CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING_ PERMIT Address:17621 W Country Club Drive Permit#: 1943 Parcel#:00816000004700 Valuation:0.00 OWNER ,APPLICANT CONTRACTOR Name:BRAULIO CARLOS&KARI Name:Brennan Heating Name:Brennan Heating Address; 17621 W COUNTRY CLUB DR Address:4601 S 134th Place Address:4601 S 134th Place City,Slate Zip:ARLINGTON,WA 98223-4650 City,Slate'Zip:Seattle,WA 98168 City,Slate Zip:Sealtle,WA 98168 Phone: Phone:106-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 1341h Place Address: City,Stale,Zip:Seattle,WA 98168 City,Slate,Zip: Phone:206-248-7900 Phone: LAC#:BRENNHA97IR9 EXP: 1 212 9/2 0 1 9 L.IC#: JOB,DESCRIPTION r PERMI r TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONS'1,TYPE: `1B DWELLING UNITS: j OCC GROUP: R3 BUILDINGS; OCC LOAD: PERMIT APPROVAL I AGREE TO COMPI.Y WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTIIORIZE•D THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LA13OR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.2T THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HAS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USI:OR OCCUPY A BUILDING OR ST'RUCPURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC]10/IRCI 10, SAUISTAX NOT110Et Seles tax relating to construction and construction materials in the City of Arlil t T on your sales tax return Iorm an < d i f�l gton#3101. 14 wit7I11 Signature Print Name Date elemed By Dale CONDITIONS Approved as submitted. Adhere to the installation of furnace model #EL280DF09OP48B AFUE 80%and A/C unit model #EL16XC1-048 SEER 16. Additional requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. l THIS PERMIT AUTHORIZS ONLY IT1E WORK NOTED.'MIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY I CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATH PERMISSION PERMIT FEES Date Description Fee Amount 3/2/2018 Furnace $25.00 3/2/2018 Mechanical Permit Base Fee $25.00 3/2/2018 Processing/Technology Fee $25.00 Total Due: 575,00 Total Payment: $0 00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17621 W Country Club Drive Permit#: 1843 Parcel#:00816000004700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BRAULIO CARLOS&KARI Name:Brennan Heating Name:Brennan Heating Address: 17621 W COUNTRY CLUB DR Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223-4650 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#:BRENNHA97I R9 EXP: 12/29/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: 2 CONST.TYPE: ` 13 DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of ANl' I e rt on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date eased By Date CONDITIONS Approved as submitted. Adhere to the installation of furnace model #EL280DF09OP48B AFUE 80%and A/C unit model #ELI6XC1-048 SEER 16. Additional requirements: 3" concrete pad with seismic bracing attached to pad, provide electrical disconnect, lines shall be insulated -the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 3/2/2018 Furnace $25.00 3/2/2018 Mechanical Permit Base Fee $25.00 3/2/2018 Processing/Technology Fee $25 00 Total Due: $75.00 Total Payment: $0 00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 3/2/2018 Permit Number 1843 Project Name Braulio Applicant Name Brennan Heating Applicant Address 4601 S 134th Place City,State,Zip Seattle,WA 98168 Contact Jaimie How Phone 206-248-7900 Email jaimie@brennanheating.com Permit Type Residential Mechanical Site Address 17621 W Country Club Drive Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace Gas Furnace and add A/C Assigned To Kristin Foster Property Owner Parcel Address Legal Owner Phone Zoning 00816000004700 17621 W COUNTRY CLUB BRAULIO CARLOS& 111 Single Family Residence- DR KARI Detached Contractors Contractor Primary Phone Email Contractor Type License License# Name Contact Brennan 206-248 (MECHANICAL Labor and Heatinglaimie How 7900 aimie@brennanheating.com,CONTRACTOR Industries 13RENNHA971 R Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.00 Notes Date Note 3/2/2018 Furnace model#EL280DF090P48B AFUE 80%A/C model#EL16XC1-048 SEER 16 Uploaded Files I Upload File Date File Uploaded By 3/2/2018 6 58 10 AM 11843 Apphcahon and Specs,r)dt Foster. Kristin I x 3/2/2018 BRENNAN HEATING&A/C LLC Search L&I Washington State Department of " Labor & Industries BRENNAN HEATING &A/C LLC Owner or tradesperson 4601 S 134TH PL SEATTLE,WA 98168 Principals 206-248-7900 ERDAHL,DARRIN PAUL,PARTNER/MEMBER KING County Doing business as BRENNAN HEATING&A/C LLC WA UBI No. Business type 602 346 866 Limited Liability Company Governing persons DARRIN P. ERDAHL ERIC L BEARDEMPHL; JAMES JOLLY; STEFANIE ERDAHL; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BRENNHA971R9 Effective—expiration 12/29/2003-12/2912019 Bond FEDERATED MUTUAL INS CO $12,000.00 Bond account no. 9127230 Received by L&I Effective date 11/04/2004 12/22/2004 Expiration date Until Canceled Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9820726 Received by L&I Effective date 06/06/2017 07/13/2015 Expiration date 07/13/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings https://secure.ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA97l R9&SAW= 1/3 3/2/2018 BRENNAN HEATING&A/C LLC No lawsuits against the bond or savings accou 'luring the previous 6 year period. 1 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PDOVE00515 Satisfied Issue date RCW/WAC 01/26/2018 18.106.020 Violation city Violation amount SEATTLE $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required. Infraction no. PPEJP00330 Satisfied Issue date RCW/WAC 09/14/2012 18.106.020 Violation city Violation amount Seattle $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.On 9/11/12,Brennan Heating& A/C LLC employed Levy Malcom Steere to perform plumbing related duties without proper plumbing certification. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 803,761-08 Doing business as BRENNAN HEATING&AIR CONDIT Estimated workers reported Quarter 4 of Year 2017"Greater than 100 Workers" L&I account contact T4/NIKKI BUTLER(360)902-4918-Email:BUT0235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. hfps://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA971 R9&SAW= 2/3 3/2/2018 BRENNAN HEATING&A/C LLC NJashinglon State Dept of Labor&Industries.Use of+his site is subject to the laws or`the skate of Washington, https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA971 R9&SAW= 3/3 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone (360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION, Project Address: 1PI'2 (_(�l� oy )a_6`/ C y h_ ___ iC _ —LL.YS-� ► L-. c Project Description: �l—.l�) _ (Z y� �� Owner: LA �� _ ICE-r I `f rA t) i 0 --- - — Address: - Phone: �JF5 �-�'D rj'� Imo_ - Email: - - Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-7900 Email: Jaimie@brennanheating.com Applicant Signature: - 61 Electronic Signature if submitting on-line 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration:12129 C)11 Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONL Received Permit #: I�' Accepted by: _ Date: - crD 95 2nTaT RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances CAR..os 1. µpiL-% X-c 6-L% w c.00.n�'+ L vri ov, T y' Ipac.K ?M?Ot'l I I GAaa6i� 30' .i A- Couh,fi•( C..�JCS D1� . SPECIFICATIONS General Model No. All Regions EL16XC1-041 EL16XC1-042 EL16XCl-047 EL16XCl-048 EL16XC1-060 Data Nominal Tonnage 3.5 3.5 4 4 5 Connections Liquid line(o.d.)-in. 318 3/8 3/8 3/8 3/8 (sweat) Suction line(o.d.)-in. 7/8 718 7/8 7/8 1-1/8 Refrigerant R-410A charge furnished 9 lbs.9 oz. 8 lbs. 12 oz. 11 lbs.0 oz. 9 lbs. 12 oz. 12 lbs.0 oz. Outdoor Net face area-sq.ft. Outer coil 21.00 1 21.00 22.17 21.00 29.09 Coil Inner coil 20.25 20.25 21.33 20.25 28.16 Tube diameter-in. 5116 5/16 5116 5/16 5/16 No.of rows 2 2 2 2 2 Fins per inch 22 22 22 22 22 Outdoor Diameter-in. 22 22 26 22 26 Fan No,of blades 3 3 4 4 3 Motor hp 1/6 1/6 1/3 /. 113 Cfm 3050 3050 4400 3600 4550 Rpm 825 825 825 825 825 Watts 190 190 310 310 310 Shipping Data-lbs.1 pkg, 227 234 272 255 284 ELECTRICAL DATA Line voltage data-60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 'Maximum overcurrent protection(amps) 30 40 35 40 50 'Minimum circuit ampacity 19.3 23.4 21,9 24.2 29.6 Compressor Rated load amps 14.7 17.9 16A 18.0 22.2 Locked rotor amps 75 112 105.5 117 127.9 Power factor 0.96 0.96 0.98 0.96 0.98 Outdoor Fan Motor Full load amps 1 1 1.8 1.7 1.8 Locked rotor amps 1.9 1.9 2.9 3.2 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 93M06 Factory Compressor Hard Copeland 1 OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47,135 Freezestat 3/8 in.tubing 93G35 5/8 in.tubing 5OA93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 'Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-65-30 L15-65-40 Line Sets L15-65-50 Field Fabricate NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 1s n.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set length and addlilonal refrigerant charge required. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 -1.5 to 5 Ton Air Conditioner 1 Page 7 SPECIFICATIONS Gas Model No. EL28ODF07OP36A EL28ODF09OP48B EL28ODF11OP60C Heating Performance 1 AFUE 80% 80% 80% High Input-Btuh 66,000 88,000 110,000 Fire Output-Btuh 52,000 69,000 87,000 Temperature rise range-°F 30-60 35-65 40-70 Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5 1 10.0 Nat.Gas/LPG/Propane Low Input-Btuh 43,000 57,000 72,000 Fire Output-Btuh 35,000 46,000 59,000 Temperature rise range-°F 20-50 20-50 25-55 Gas Manifold Pressure(in,w.g.) 1.7/4.9 1.7/4.9 1.7/4.9 Nat.Gas/LPG/Propane High static-in.w.g. Heating 0.5 0.5 0.5 Cooling 0.5 0.5 0.5 Connections Flue connection-in.round 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 10 11-1/2 x 10 Blower Motor output-hp 1/3 1/2 1 Tons of add-on cooling 2-3.5 3-4 4-5 Air Volume Range-cfm 717-1562 917-1929 1517-2760 Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 6.1 8.2 11.5 Maximum overcurrent protection 15 15 15 Shipping Data lbs.- 1 package 128 140 160 NOTE-Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating For non-weatherized furnaces. OPT16NAL ACCESSORIES-ORDER SEPARATELY "A"Width "B"Width I "C"Width Models Models Models CABINET ACCESSORIES Downflow Combustible Flooring Base I 11 M59 11 M60 I 11 M61 DOWNFLOW FILTER KITS Downflow Filter Kit 51W06 51W07 51W08 No. and Size of filter-in. (1)20 x 20 x 1 (2)16 x 20 x 1 (2)16 x 20 x 1 NIGHT SERVICE KIT Night Service Kit I 84W46 I 84W46 I 84W46 EL28ODF/Page 5