Loading...
HomeMy WebLinkAbout5209 Cemetery Rd_BLD524_2025 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 5209 Cemetery Rd Permit#• 524 Parcel#:00426400002600 Valuation:0,00 OWNER APPLICANT CONTRACTOR. . Name:CRAWFORD TYLER do HEATHER Name: Brennan Heating Name:Brennan Heating Address:5209 198TH ST NF Address:4601 S 134th PI Address:4601 S 134th Place City,State Zip:ARLINGTON, WA 98223 City,State Zip:Seattle,WA 9R 168 City,State Zip:Seattle,WA 981 68 Phone: Phonc:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name Address:4601 S 134th PI Address: City, State;Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC p:BRENNHA97I129 EXP: 12/2W2015 L I C#: EXP: JOB AESt)LIPTTON x `` ' , r �, �� ,�; ,+; r �,wr ��+�; ; �'u ;r °t o,r� �7t�w, ? � �, I;,� L � - PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST.TYPE: I D%kT,LLINGUNITS- OCCGROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASIIINGTON RELATING TO f WORKMEN'S COMPF'NSATION INSURANCE AND RCW 18.27. THIS APPLICATION 1S NOT A PERMIT UNTIL SIGNED 13Y THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FGCS ARF.PAID. 1 IT 1S UNLAWFUL TO USE OR OCCUPY A BUILDING;OR STRUCTURE UNTIL A FINAL,INSPEC.'rION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY IIAS BEEN GRANTED. IBCt IO/IRCt 10. "TA . Y ''CF: Sales tax relating to construction and construction materials in the City of Arling4,nus he repor(ed un your,sales tax return h rm and coded C ity of Arlington 13 01, � •t� aw l � 1� 112�1 /�f Signature Prim Name Date Ruled By rate CONDITIONS Model #MS8-HO-18P - SEER 18.00 - HSPE 10.20 - Requirements: 3" concrete pad with seismic bracing attached to pad. Per C403.2.8.1 Lines shall be insulated, use of adhesive tapes are prohibited. THIS PERMIT AUTIIORIZS ONLY TIIE WORK NOTED.THIS PERM11'COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS, DRIVEWAYS,MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION_ i PERMIT FEES Date Description Fee Amount 11/24/2014 Heat Pump $25,00 11/24/2014 Mechanical Permit Base Fee $25.00 i Total Due: $50.00 Total Payment: $0M0 1 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning(Pr afternoon CITY OF ARLINGTON • 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 5209 Cemetery Rd Permit#: 524 Parcel#:00426400002600 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:CRAWFORD TYLER& HEATHER Name:Brennan Heating Name:Brennan Heating Address:5209 198TH ST NE Address:4601 S 134th PI Address:4601 S 134th Place City, State Zip:ARLINGTON,WA 98223 City, State Zip: Seattle, WA 98168 City, State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Brennan Heating Name: Address:4601 S 134th PI Address: City, State,Zip: Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#:BRFNNHA97I R9 EXP: 12/29/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlingtonmeported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Reloa. fay Date CONDITIONS Model # MS8-HO-18P - SEER 18.00 - HSPE 10.20 - Requirements: 3" concrete pad with seismic bracing attached to pad. Per C403.2.8.1 Lines shall be insulated, use of adhesive tapes are prohibited. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/24/2014 Heat Pump $25.00 11/24/2014 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon NOV-21-2014 10:36 From: T,"—)62487905 Pa9e:9/9 ?Qs 3S� 'ram f-tary q �.,aG Pt;o�wci `� Jam' GaRA�� OF ARLING`OUM ';ts9LDING DEPARTMEW17 ( 2 BY 40' NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR N11 I L M, 3 C! MS 8 T-1 S P ffi c a L i o ns Outdoor Unit MS8-HO-09L MS8-HO-12L MS8-HO-18P MS8-HO-24P MS8-HO-30P Model Numbers MS8-CO-09L MS8-CO-1 2L MS8-CO-18P MS8-CO-24P MS8-1-10-09P MS8-1-10-1 2P MS8-CO-09P MS8-CO-1 2P HSPF 9.80 9.60 10.20 10.20 8.20 SEER 22.00 20.00 18.00 18-00 16.00 Sound(dBA) 53 55 55 56 62 Dimensions HxWxD(in) 21-1/4 x 30 x.12-5/8 23-1/4 x 30 x 12-5/8 27-5/8 x 35 x 15-5/8 31-1/8 x 36 x 16-7/8 31-1/8 x 36 x 16-7/8 HxWxD(mm) 540 x 762 x 320 1591 x 762 x 320 702 x 890 x 397 790 x 914 x 427 790 x 914 x 427 Indoor Unit MS8-HI-09L MS8-HI-12L MS8-1-11-18P MS8-HI-24P MS8-HI-30P Model Numbers MS8-CI-09L MS8-CI-1 2L MS8-CI-1 8P MS8-CI-24P MS8-HI-09P MS8-HI-12P MS8-Cl-09P MS8-Cl-12P Sound(dBA) 26-34 26-36 35-44 37-45 48-57 CFM Low Speed 220 215 325 355 645 Medium Speed 255 255 385 410 675 High Speed 295 275 460 470 705 Turbo Speed 330 305 500 1590 NA Dimensions Dimensions HxWxD(in) 10-7/8 x 33-3/8 x 7 10-7/8 x 33-3/8 x 7 11-3/4 x 37 x 8 12-3/8 x 39-3/4 x 8-5/8 12-7/8 x 53-1/8 x 10 HxWxD(mm) 275 x 848 x 180 275 x 848 x 180 298 x 940 x 203 315 x 1008 x 219 326 x 1349 x 253 Note:Due to Lennox'ongoing commitment to quality,all specifications,ratings and dimensions are subject to change without notice. **Based on sound pressure levels of the MS8-CI-09L UUCP Alk ID.......... W LENN�X W �( �s Intertek Innovation never felt so good.* For a complete list of the registered and common law trademarks owned by Lennox Industries Inc.,please visit www.lennox.com. www,lennox.com 1-800-9-LENNOX C 2013 Lennox Industries Inc. PC72083 02/13 (10F75) r- RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community&Economic Development City of Arlington• 18204 S9th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHFN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: Project Description:`I Y) L S S 1 1-cA �, ✓- ( Owner: -Eg� -�- Address:,, II Phone: `i a 5 • • �- Email: Applicant: Brennan Heating Address.4601 S 134th PI Seattle 98168 Phone: 206-248-7900 , Email: Jaimie@brennanheating.com Applicant Signatur Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit#: 5v�q _ Accepted by Date: 1 t 1-2-q RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community&Economic Development City of Arlington•18204 59th Ave NE -Arlington,WA 98223 - Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ i Heat Pump ❑ Freestanding Stove U Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System Boiler U Gas Piping ❑ Storage Tank ❑ AC Unit Q Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size. Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances SPECIFICATIONS- HEAT PUMP SYSTEMS OUT UNIT DOOR Tonnage 1 0.75 1 0.75 1 1 1.5 2 2.5 Outdoor Unit Model No. MS8-HO-09L MS8-HO-09P MS8-HO-12L MS8-HO-12P MS8-H048P MS8-HO-24P MSMO30P Cooling Low 3,500 3,500 3,100 3,100 5,970 9,600 9,500 Capacity(Btuh) Standard 9,000 9,000 12,000 12,000 18,000 21,400 28,000 High 9,600 9,600 13,000 13,000 22,350 25,000 30,000 Heating Low 2,200 2,200 2.400 2,400 5,970 4,300 10,000 Capacity(Btuh) Standard 9,800 9,800 13,000 13,000 18.000 23,000 28,400 High 11,000 11,000 14,000 14,000 22,350 26,000 33,000 Connections Small line o.d.-flare 1/4 1/4 114 1/4 114 1/4 1/4 (in.) Large line o.d.-flare 3/8 3/8 3/8 3/8 1/2 5/8 5/8 Ambient Temperature Cooling 41 - 115 0-109 41 -115 0- 109 14-109 14-109 5-109 Operating Range-°F Heating 5-86 -5-75 5-86 -5-75 19-75 19-75 17-75 t Refrigerant(R-410A)furnished 2 lbs.6 oz. 2 lbs.14 oz. 2 lbs.14 oz. 2 lbs.14 oz. 3 lbs. 1 oz. 3 lbs.9 oz. 5 lbs.5 oz. Outdoor Net face area-sq,ft. 3.95 4.08 4.08 4.49 5.96 7.66 7.66 Coil Tube diameter-in, 1/4 114 3/8 3/8 1/4 1/4 5/16 Number of rows 2 2 2 2 2 2 2 Fins per inch 18 20 18 20 20 20 18 Outdoor Diameter-in. 15-5/8 15-3/4 15-5/8 15-314 20-1/2 21-314 21-3/4 Fan Motor No.of blades 3 3 3 3 3 3 3 Cfm 1120 940 1120 940 1885 2355 2355 Rpm 650/900 680/900 680/900 680/900 800 800 830 Shipping Data-lbs. Outdoor Unit 110 110 119 119 110 135 164 ELECTOICAL DATA Line voltage data-60 hz-1 ph 115V 208/230V 115V 208/230V 208/230V 208/230V 2081230V Z Max,overcurrent protection(amps) 35 15 40 15 20 25 30 3 Minimum circuit ampacity 22 10 23 10 13 16 20 Compressor Rated load amps 16 7.2 17.5 6.5 9.7 11 13.5 Compressor Power Input(W) 600 860 1200 860 1200 1420 2450 Outdoor Rated load amps 0.17 0.13 0.17 0.13 0.28 1.1 0.45 Fan Motor Output(W)1 40 1 30 40 30 60 90 90 MATCHING .•• UNIT - Indoor Unit Model No.I MSS-HI-09L MSB-HI-09P MS8-HI-12L MS8-HI-12P MSB-HI-18P MS8-HI-24P MS8-HI-30P Connections Small lineo.d.-flare 1/4 1/4 1/4 114 1/4 1/4 1/4 (in.) Large line o.d.-flare 3/8 3/8 3/8 3/8 1/2 518 5/8 Indoor Blower Turbo 330 306 300 335 500 590 --- Air Volume High 295 277 275 277 459 470 705 (cfm) Medium 255 253 255 1 253 383 410 675 Low 220 218 215 218 324 355 645 Indoor Blower Turbo 1260/1320 1260/1320 1260/1280 1330/1350 1500/1500 1500/1450 --- RPM High 1050/1200 1100/1200 1070/1050 1100/1170 1200/1250 1200/1150 1410/1410 (Cooling/Heating) Medium 920/1100 950/1100 900/980 950/1050 1050/1150 1050/1020 1280/1280 Low 7301950 750/950 730/920 750/950 90011050 900/950 1200/1200 Indoor Net face area-sq.ft. 1.85 1.65 1.85 1.65 2.33 3.23 14.8 Coil Tubediameter-in. 1/4 1/4 1/4 1/4 114 1/4 1/4 Number of rows 2 2 2 2 2 2 2 Fins per inch 18 20 18 20 20 18 18 Indoor Diameter x Length-in. 3.6 x 25.4 3.6 x 25.4 3.6 x 25.4 3.6 x 25.4 3.9 x 28 3.9 x 30 4.25 x 20.5 Blower Type Cross-flow Cross-flow Cross-flow Cross-flow Cross-flow Cross-flow Cross-flow Shipping Data -lbs. Indoor Unit 37 37 37 37 38 47 60 91LECT1P, DATA Line voltage data-60 hz-1 ph 115V 208/230V 115V 2081230V 208/230V 208/230V 2081230V Rated Load Amps 0.38 0.20 0.38 0.20 0.32 0,24 0.40 Output(W) 20 20 20 20 20 60 40 NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. 'Refrigerant charge sufficient for 26 ft.of lineset. z HACR type circuit breaker or fuse Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. °Rated Input MS8C1MS8H-Mini-Split Systems I Page 9