17831 83rd Dr Ne_BLD4162_2025
17831 83rd Dr. NE Arlington, WA 98223 Replace existing furnace with new Diana R Drainville Trust - Diana Stonier 17831 83rd Dr. NE Arlington WA 98223 503.505.0607 dianastonier@gmail.com Pilchuck Heating LLC 1429 Ave. D #224 Snohomish WA 98290 425.585.0659 pilchuckheating@pilchuckheating.com Pilchuck Heating LLC 1429 Ave. D #224 Snohomish WA 98223 PILCHHL823LN 06/15/2022 425.585.0659 pilchuckheating@pilchuckheating.com DC96VE0603BXD 96 ✔ ✔ 09/28/2021 Danielle Shadley CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 17831 83RD DR NE Permit #: 4162 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00958500010800 DATE OF ISSUANCE. Scope of Work: Replace existing furnace with new Valuation: .00 OWNER APPLICANT CONTRACTOR DRAINVILLE DIANA R TRUST Pilchuck Heating LLC Pilchuck Heating 17831 83RD DR NE 1429 Ave D #224 1429 Avenue D, #224 ARLINGTON, WA 98223-4039 Snohomish, WA 98290 Snohomish, WA 98290 4255850659 425-501-5480 LIC: PILCHHL823LN EXP: 06/15/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Pilchuck Heating 1429 Avenue D, #224 Snohomish, WA 98290 425-501-5480 LIC #: PILCHHL823LN EXP: 06/15/2022 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 09/29/2021 Signature Print Name Date Released By Date CONDITIONS Adhere to approved plans. Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/29/2021 Inspection Fee $75.00 09/29/2021 Forced Air Heat $15.00 09/29/2021 Mechanical Base $25.00 09/29/2021 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon DC96VE Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE Heating Input: 40,000 - 100,000 BTU/h â– Contents Nomenclature ........................................2 Product Specifications ...........................3 Dimensions ............................................4 Airflow Specifications ............................5 Wiring Diagram ....................................10 Accessories ..........................................11 â– Standard Features â– Cabinet Features • Energy-efficient multi-speed ECM blower motor • Designed for multi-position installation: • Heavy-duty stainless-steel DC96VE: Counter flow, horizontal left or right tubular heat exchanger • Certified for direct vent (2-pipe) or non-direct vent (1-pipe) • Stainless-steel secondary heat exchanger • Easy-to-install top venting with optional side venting • Two-stage gas valve provides quiet, • Convenient left or right connection economical heating for gas and electrical service • Durable Silicon Nitride igniter • Cabinet air leakage (QLeak) ≤ 2% • Quiet two-speed induced draft blower • Heavy-gauge steel cabinet with durable finish • Self-diagnostic control board with constant • Fully insulated heat exchanger and blower section memory fault code history output to a LED • Airtight solid bottom or side return • Color-coded low-voltage terminals with provi- with easy-cut tabs for effortless removal sions for electronic air cleaner and humidifier in bottom air-inlet applications • Low continuous fan speed options offer quiet air circulation • Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019 • AHRI Certified; ETL Listed * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 6-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DC96VE www.daikincomfort.com 07/20 Supersedes 10/19 Nomenclature D C 96 V E 060 3 B N A A 1 2 3,4 5 6 7,8,9 10 11 12 13 14 Brand Minor  Revision D  -† Daikin  Brand  A  -† Initial  Release    B  -† 1st  Revision Configuration M  -† Upflow/Horizontal Major  Revision C  -† Downflow/Horizontal  A  -† Initial  Release    B  -† 1st  Revision AFUE 97  –  97-Ââ€98%  AFUE 92  -† 92%  AFUE NOx 96  –  96%  AFUE    N  -†  Low  Nox  (40ng/J) Gas  Valve Cabinet  Width M  -† Modulating H  -† Convertible  Two-Ââ€Stage    B  -† 17½" V  -† Two  Stage  S  -† Single  Stage    C  -† 21"    D  -† 24½" Motor C   Variable  Speed  ECM  /  Communicating Maximum  CFM E  - Multi-Speed  ECM  S - Multi-Speed PSC    2  -†   800  CFM    3  -† 1200  CFM MBTU/h    4  -† 1600  CFM 040  -† 40,000  BTU/h 100  -† 100,000  BTU/h    5  -† 2000  CFM 060  -† 60,000  BTU/h 120  -† 120,000  BTU/h 080  -† 80,000  BTU/h 2 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 3 Product Specifications DC96VE DC96VE DC96VE DC96VE 0403BNA 0603BNA 0803BNA 1005CNA Heating Data High Fire Input¹ 40,000 60,000 80,000 100,000 High Fire Output¹ 38,400 57,600 76,800 96,000 Low-Fire Steady-State Input¹ 28,000 42,000 56,000 70,000 Low-Fire Steady-State Output¹ 26,880 40,320 53,760 67,200 AFUE² 96 96 96 96 Temperature Rise Range (°F) 25 - 55 25 - 55 40 - 70 35 - 65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" No. of Burners 2 3 4 5 Circulator Blower Available AC @ 0.5†ESP 1.5 - 3 1.5 - 3 1.5 - 3 4 - 5 Size (D x W) 10" x 8" 11" x 8" 11" x 8" 11" x 10" Horsepower @ 1075 RPM 1/2 1/2 1/2 1 No. of speeds 5 5 5 5 Electrical Data Min. Circuit Ampacity4 8 8 8 13.3 Max. Overcurrent Device (amps)5 15 15 15 15 Shipping Weight (lbs) 112 115 118 140 ¹ Natural Gas BTU/h; for altitudes 0-4500'’ above sea level, reduce input rating by 4% for each 1000' above 4500' altitude. ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). â´ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. âµ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 2 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 3 Dimensions A 6½ B 2â… C 1â… 2½ 18¼ 1â…ž 1â…œ 23 1â…ž Alternate Vent/ 1½ Low-Voltage Electrical Outlet Low-Voltage Electrical Outlet 14 Alternate Gas Alternate Gas Supply High-Voltage Electrical Outlet 25â…› 34½ 25â…› 14â…ž 14¾ 14¾ 11â…œ 11â…œ 6â…ž 6â…ž 4â…› High-Voltage Drain Trap Holes 18â…› D Electrical Outlet Standard Drain Trap 2 Unfolded Flanges Unfolded Flanges 2½ 2 20â…› 3½ E Folded Flanges 28¾ Folded Flanges 2â… Right-Side View Front View Right Side Exterior Air Drain Trap Holes Air Discharge Discharge Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 3" NC 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. AIR DISCHARGE AIR RETURN MODEL A B C D E DC96VE0403BNA 17½" 14â…" 14" 14½" 16" DC96VE0603BNA 17½" 14â…" 14" 14½" 16" DC96VE0803BNA 17½" 14â…" 14" 14½" 16" DC96VE1005CNA 21"†18â…›" 17½" 18" 19½" 4 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 5 Airflow Data — DC96VE0403BNA COOLING DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-1 S1-2 S1-3 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM Ylo 647 576 511 449 387 335 280 252 **OFF OFF OFF Y 1229 1181 1150 1117 1078 1035 1002 964 Ylo 1137 1096 1056 1018 981 940 897 859 ON OFF OFF Y 647 576 511 449 387 335 280 252 Ylo 1137 1096 1056 1018 981 940 897 859 ON ON OFF Y 1229 1181 1150 1117 1078 1035 1002 964 Ylo 647 576 511 449 387 335 280 252 OFF ON OFF^ Y 743 688 628 572 515 459 408 364 Ylo 647 576 511 449 387 335 280 252 OFF OFF ON^ Y 939 894 846 806 759 706 661 614 Ylo 1137 1096 1056 1018 981 940 897 859 OFF ON ON^ Y 743 688 628 572 515 459 408 364 Ylo 939 894 846 806 759 706 661 614 ON OFF ON Y 1229 1181 1150 1117 1078 1035 1002 964 Ylo 939 894 846 806 759 706 661 614 ON ON ON^ Y 1137 1096 1056 1018 981 940 897 859 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED CONTINUOUS FAN DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S2-2 S2-3 S2-4 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM **OFF OFF OFF G 743 688 628 572 515 459 408 364 ON OFF OFF G 939 894 846 806 759 706 661 614 ON ON OFF G 1137 1096 1056 1018 981 940 897 859 OFF ON OFF G 647 576 511 449 387 335 280 252 OFF OFF ON G 1229 1181 1150 1117 1078 1035 1002 964 OFF ON ON G 743 688 628 572 515 459 408 364 ON OFF ON G 743 688 628 572 515 459 408 364 ON ON ON G 743 688 628 572 515 459 408 364 HEATING DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-4 S2-1 Tstat Call CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM W1 743 33 688 36 628 40 572 44 515 48 459 408 364 **OFF OFF W2 939 38 894 40 846 42 806 44 759 47 706 661 614 W1 1137 NA 1096 NA 1056 NA 1018 NA 981 N/A 940 897 859 ON OFF W2 939 38 894 40 846 42 806 44 759 47 706 661 614 W1 1137 NA 1096 NA 1056 NA 1018 NA 981 N/A 940 897 859 ON ON W2 647 55 576 NA 511 NA 449 NA 387 NA NA NA NA W1 647 38 576 43 511 49 449 55 387 64 335 280 252 OFF ON W2 1229 29 1181 30 1150 31 1117 32 1078 33 1035 1002 964 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Minimum Filter Sizes DC96VE DC96VE DC96VE DC96VE 0403BN* 0603BN* 0803BN* 1005CN* Filter Size (in²) (Qty) (2) 10 x 10 or (1) 16 x 25 (Top Return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 4 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 5 Airflow Data — DC96VE0603BNA COOLING DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-1 S1-2 S1-3 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM Ylo 1149 1104 1057 1017 963 918 865 822 **OFF OFF OFF Y 1236 1189 1149 1101 1066 1017 969 928 Ylo 782 629 547 469 396 333 N/A N/A ON OFF OFF Y 1149 1104 1057 1017 963 918 865 822 Ylo 782 629 547 469 396 333 N/A N/A ON ON OFF Y 1236 1189 1149 1101 1066 1017 969 928 Ylo 1149 1104 1057 1017 963 918 865 822 OFF ON OFF^ Y 894 846 780 720 660 603 554 505 Ylo 1149 1104 1057 1017 963 918 865 822 OFF ON ON Y 1328 1287 1249 1215 1170 1131 1085 1046 Ylo 782 629 547 469 396 333 N/A N/A ON OFF ON Y 894 846 780 720 660 603 554 505 Ylo 1328 1287 1249 1215 1170 1131 1085 1046 OFF ON OFF^ Y 1236 1189 1149 1101 1066 1017 969 928 Ylo 1328 1287 1249 1215 1170 1131 1085 1046 OFF ON OFF^ Y 782 629 547 469 396 333 N/A N/A ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED CONTINUOUS FAN Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S2-2 S2-3 S2-4 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM **OFF OFF OFF G 894 846 780 720 660 603 554 505 ON OFF OFF G 1328 1287 1249 1215 1170 1131 1085 1046 ON ON OFF G 782 629 547 469 396 333 290 251 OFF ON OFF G 1149 1104 1057 1017 963 918 865 822 OFF OFF ON G 1236 1189 1149 1101 1066 1017 969 928 OFF ON ON G 894 846 780 720 660 603 554 505 ON OFF ON G 894 846 780 720 660 603 554 505 ON ON ON G 894 846 780 720 660 603 554 505 ** Factory Default HEATING Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S1-4 S2-1 Tstat Call CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM W1 894 41 846 44 780 47 720 51 660 56 603 554 505 **OFF OFF W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 W1 782 47 629 NA 547 N/A 469 N/A 396 N/A N/A N/A N/A ON OFF W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 W1 782 47 629 NA 547 N/A 469 N/A 396 N/A N/A N/A N/A ON ON W2 1149 46 1104 48 1057 50 1017 52 963 55 918 865 822 W1 1149 32 1104 33 1057 35 1017 36 963 38 918 865 822 OFF ON W2 1236 43 1189 44 1149 46 1101 48 1066 50 1017 969 928 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 7 Airflow Data — DC96VE0803BNA COOLING DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-1 S1-2 S1-3 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM Ylo 894 842 784 726 682 618 562 519 **OFF OFF OFF Y 1111 1068 1025 984 941 885 860 801 Ylo 750 644 569 507 442 388 328 N/A ON OFF OFF Y 894 842 784 726 682 618 562 519 Ylo 750 644 569 507 442 388 328 N/A ON ON OFF Y 1111 1068 1025 984 941 885 860 801 Ylo 894 842 784 726 682 618 562 519 OFF ON OFF Y 1221 1172 1128 1087 1049 1005 959 922 Ylo 894 842 784 726 682 618 562 519 OFF ON ON Y 1311 1293 1249 1203 1172 1122 1088 1041 Ylo 750 644 569 507 442 388 328 N/A ON OFF ON Y 1221 1172 1128 1087 1049 1005 959 922 Ylo 1311 1293 1249 1203 1172 1122 1088 1041 OFF ON OFF^ Y 1111 1068 1025 984 941 885 860 801 Ylo 1311 1293 1249 1203 1172 1122 1088 1041 OFF ON OFF^ Y 750 644 569 507 442 388 328 N/A ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED CONTINUOUS FAN Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S2-2 S2-3 S2-4 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM **OFF OFF OFF G 1221 1172 1128 1087 1049 1005 959 922 ON OFF OFF G 1311 1293 1249 1203 1172 1122 1088 1041 ON ON OFF G 750 644 569 507 442 388 328 288 OFF ON OFF G 894 842 784 726 682 618 562 519 OFF OFF ON G 1111 1068 1025 984 941 885 860 801 OFF ON ON G 1221 1172 1128 1087 1049 1005 959 922 ON OFF ON G 1221 1172 1128 1087 1049 1005 959 922 ON ON ON G 1221 1172 1128 1087 1049 1005 959 922 ** Factory Default HEATING Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S1-4 S2-1 Tstat Call CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM W1 1221 40 1172 42 1128 44 1087 45 1049 47 1005 959 922 **OFF OFF W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 W1 750 66 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A ON OFF W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 W1 750 NA 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A ON ON W2 894 N/A 842 N/A 784 N/A 726 N/A 682 N/A 618 562 519 W1 894 55 842 59 784 NA 726 NA 682 N/A 618 562 519 OFF ON W2 1111 63 1068 66 1025 69 984 NA 941 NA 885 N/A 801 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 7 Airflow Data — DC96VE1005CNA COOLING DIP Switches Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 S1-1 S1-2 S1-3 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM Ylo 1637 1577 1528 1467 1410 1369 1307 1256 **OFF OFF OFF Y 2069 2009 1978 1932 1923 1876 1834 1773 Ylo 1477 1422 1364 1301 1244 1190 1135 1078 ON OFF OFF Y 1637 1577 1528 1467 1410 1369 1307 1256 Ylo 1477 1422 1364 1301 1244 1190 1135 1078 ON ON OFF Y 2069 2009 1978 1932 1923 1876 1834 1773 Ylo 1637 1577 1528 1467 1410 1369 1307 1256 OFF ON OFF^ Y 1300 1234 1175 1109 1052 992 928 866 Ylo 1637 1577 1528 1467 1410 1369 1307 1256 OFF ON ON Y 1866 1817 1774 1729 1684 1637 1593 1552 Ylo 1477 1422 1364 1301 1244 1190 1135 1078 ON OFF ON Y 1300 1234 1175 1109 1052 992 928 866 Ylo 1866 1817 1774 1729 1684 1637 1593 1552 OFF ON OFF^ Y 2069 2009 1978 1932 1923 1876 1834 1773 Ylo 1866 1817 1774 1729 1684 1637 1593 1552 OFF ON OFF^ Y 1477 1422 1364 1301 1244 1190 1135 1078 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED CONTINUOUS FAN Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S2-2 S2-3 S2-4 Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM **OFF OFF OFF G 1300 1234 1175 1109 1052 992 928 866 ON OFF OFF G 1866 1817 1774 1729 1684 1637 1593 1552 ON ON OFF G 1477 1422 1364 1301 1244 1190 1135 1078 OFF ON OFF G 1637 1577 1528 1467 1410 1369 1307 1256 OFF OFF ON G 2069 2009 1978 1932 1923 1876 1834 1773 OFF ON ON G 1300 1234 1175 1109 1052 992 928 866 ON OFF ON G 1300 1234 1175 1109 1052 992 928 866 ON ON ON G 1300 1234 1175 1109 1052 992 928 866 ** Factory Default HEATING Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 DIP Switches S1-4 S2-1 Tstat Call CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM W1 1300 47 1234 50 1175 52 1109 56 1052 59 992 928 866 **OFF OFF W2 1866 47 1817 48 1774 50 1729 51 1684 52 1637 1593 1552 W1 1477 42 1422 43 1364 45 1301 47 1244 49 1190 1135 1078 ON OFF W2 1866 47 1817 48 1774 50 1729 51 1684 52 1637 1593 1552 W1 1477 42 1422 43 1364 45 1301 47 1244 49 1190 1135 1078 ON ON W2 1637 54 1577 56 1528 58 1467 60 1410 62 1369 1307 1256 W1 1637 38 1577 39 1528 40 1467 42 1410 44 1369 1307 1256 OFF ON W2 2069 43 2009 44 1978 44 1932 46 1923 46 1876 1834 1773 ** Factory Default SINGLE STAGE COOLING^ *NOT RECOMMENDED Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 8 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 9 Temperature Rise Range Chart ÷ CFM 130 140 150 Formulas1.08CFM x 1.08 FORMULASBTU/H Output BTU OUTPUT BTU/h Output = CFM x 1.08 x RiseRise = BTU OUTPUT = CFM x 1.08 x RISERISE = 110 120 100 2400 CFM 2200 2000 1800 1600 1400 1200 1100 Output BTU/h x 1,000 OUTPUT BTU/HR x 1000 1000 900 BTU Output Vs. Temperature Rise Chart800 BTU OUTPUT vs TEMPERATURE RISE CHART700 600 CFM 30 40 50 60 70 80 90 90 80 70 60 50 40 30 20 10 100 Temperature RiseTEMPERATURE RISE 8 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 9 Wiring Diagram — DC96VE GRD GN JUNCTION BOX TO GND 115VAC/1Ø/60HZ POWERSUPPLYWITH OVERCURRENT IDBLOWERTWO-STAGEPRESSURE PROTECTIONDEVICE SWITCHASSEMBLY YL PU GY OR HOT L SURFACE IGNITER OR HIGHFIRE BK WARNING:DISCONNECT POWER BEFORE YL BR PRESSURE LOWFIRE C C SWITCH OR N SERVICING. WIRING PRESSURE NO WH TO UNIT MUST BE NO PROPERLY POLARIZED SWITCH PU DISCONNECT AND GROUNDED. 2CIRCUIT 2 1 CONNECTOR OR TO115VAC/1Ø/60HZPOWERSUPPLYWITH RD HI 3 PU OVERCURRENTPROTECTIONDEVICE WH L GND N FLAME WARNING: C 2 GY C GY SENSOR TWOSTAGE NO DISCONNECTPOWER GASVALVE PM 1 BR FRONTCOVER BEFORESERVICING. PRESSURESWITCH WIRINGTOUNIT âš¡ (WHITERODGERS) MUSTBEPROPERLY POLARIZEDAND MANUALRESETROLLOUTLIMIT GROUNDED. DISCONNECT CONTROLS(SINGLECONTROLON 30kBTUAND40kBTU) BL PK OR BL CHASSIS GROUND DOOR SWITCH AUTORESETPRIMARY JUNCTIONBOX LIMITCONTROL PU GND INDUCED INDOOR 3 WH AIR DRAFT GN CIRCULATOR 2 RD BLOWER BLWR 1 BK GND GND BURNERCOMPARTMENT LINE NEUTRAL INTEGRATED CONTROL MODULE WH BLOWERCOMPARTMENT PU INTEGRATED CONTROL MODULE BK AUTORESET HUM-OUT RD AUXILIARY YL PK HUMIDIFIER NEUTRAL LIMITCONTROL HUM EAC NEUTRAL ELECTRONIC AIRCLEANER INDHI NEUTRAL ID BLWR NEUTRAL IGN INDLO HOTSURFACE BK RD BK WH IGNITER BL WH FS BK WH RD BK FLAMESENSOR EAC-H X-FMR LINE 115VAC NEUTRAL OR T1T2T3T4T5COM LINE HUM L1 NEUTRAL 5 CIRCUIT CONNECTORWHWH 40VA FUSE3A TH(5) TRANSFORMER RD R CIRC-H BK OR 24VAC AUTORESETPRIMARY RD TO LIMITCONTROL 24V THERMOSTAT CONNECTIONS N.E.C. CLASS 2 WIRE+VDC Y1 HLO(11) AUTORESETAUXILIARYLIMIT Disconnect all power before servicing or installing this unit. Multiple power CONTROLS S1 BR W1 PS1(12) C PK NO LOWFIREPRESS W2 S2 PS2(2) NO SWITCH TO C Y2 MICRO HIGHFIRE S3 BL GN PRESS.SWTICH MANUALRESETROLLOUT G LIMITCONTROLS High Voltage:sources may be present. Failure to do so may cause property damage, personal injury, or death. GY O HLI(6) BR DIAGNOSTIC DEHUM MVL(7) PU 1 4 7 10 PM LED'S YL 2 5 8 11 PK MVH(1) C 3 6 9 12 BR C MVC(8) NO OR HI C FRONTCOVER GND(4) PRESSURE GAS YLO Y W1W2 R G C TWIN SWITCH VALVE N.E.C.CLASS2WIRE 24V3A TR(9) GND Warning FUSE VAC24 VAC115 TO R GY BK ECM MTR BK INDOOR âš RD HARNESS AIR OR OR WH TO CIRCULATOR BL 5 MICRO BLWR GND 3 TRANSFORMER40 VA 12 4 N WH G GN WH BK INTEGRATEDCONTROLMODULE L BK BK C RD NOTES: WH 1.SETHEATANTICIPATORONROOMTHERMOSTATAT0.7AMPS. GND 2.MANUFACTURER'SSPECIFIEDREPLACEMENTPARTSMUSTBEUSED WHENSERVICING. BLOWER 3.IFANYOFTHEORIGINALWIREASSUPPLIEDWITHTHEFURNACE CIRCULATOR BLOWER COMPARTMENT MUSTBEREPLACEDITMUSTBEREPLACEDWITH WIRINGMATERIAL DOORSWITCH HAVINGATEMPERATURERATINGOFATLEAST105$C.USECOPPER (OPENWHEN CONDUCTORSONLY. DOOROPEN) 4.UNITMUSTBEPERMANENTLYGROUNDEDANDCONFORMTON.E.C. ANDLOCALCODES. 5.TORECALLTHELAST6FAULTS,MOSTRECENTTOLEASTRECENT, REDLEDFLASHCODE DEPRESSSWITCHFORMORETHAN2SECONDSWHILEINSTANDBY (NOTHERMOSTATINPUTS) STEADYON=INTERNALGVERROR,MICROANDFREQUENCYCHECK AMBERLEDFLASHCODE COLORCODES: EQUIPMENT GND 0 RAPID =TWINNINGERROR 0 RAPID =LOWFLAMESENSECURRENT PKPINK FIELD GND 1 1FLASH = FLAMESENSEDWHENNOFLAMESHOULDBEPRESENT 1 1FLASH =NORMALOPERATIONWITHCALLFOR BRBROWN 1STSTAGEHEAT(W1) FIELD SPLICE 2 2FLASHES =PRESSURESWITCHSTUCKCLOSED/INDUCERERROR WHWHITE 2 2FLASHES=NORMALOPERATIONWITH 3 3FLASHES =1STSTAGEPRESSURESWITCHSTUCK CALLFOR2NDSTAGEHEAT BLBLUE SWITCH (TEMP.) Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. OPEN/INDUCERERROR GYGRAY 3 3FLASHES=W2PRESENTWITHNOW1 RDRED IGNITER 4 4FLASHES =OPENLIMITSWITCH 4 4FLASHES=YPRESENTWITHNOGCALL,YLO YLYELLOW SWITCH (PRESS.) 5 5FLASHES =OPENROLLOUT/OPENFUSEDETECTED PRESENT WITHNOGCALL ORORANGE OVERCURRENT 6 6FLASHES = PRESSURESWITCHCYCLELOCKOUT PU PURPLE PROT. DEVICE GREENLEDFLASHCODE GNGREEN 7 7FLASHES =EXTERNALLOCKOUT(RETRIES) JUNCTION STEADYON=STANDBY BKBLACK 8 8FLASHES =EXTERNALLOCKOUT(RECYCLES) TERMINAL 0 RAPID = NORMALOPERATIONWITHCALLFORFAN(G) INTERNALTO 9 9FLASHES+GROUNDINGORREVERSEDPOLARITY 1 1FLASH = NORMALOPERATIONWITHCALLFOR INTEGRATED CONTROL 10 10FLASHES =GASFLOWWITHNOCALLFORHEAT LOWSTAGECOOL(YLO+G) PLUG CONNECTION 11 11FLASHES = LIMITSWITCHOPEN-BLOWERFAILURE 2 2FLASHES =NORMALOPERATIONWITHCALLFORHIGH LOW VOLTAGE (24V) STAGECOOL/OR SINGLESTAGECOOLING(Y+G) 12 12 FLASHES =IGNITORRELAYFAILURE LOW VOLTAGE FIELD 3DOUBLEFLASHES = 2NDSTAGE PRESSURESWITCH 0140F02481-A HI VOLTAGE (115V) STUCKOPEN/INDUCERERROR HI VOLTAGE FIELD 10 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 11 Accessories DC96VE DC96VE DC96VE DC96VE Model Description 0403BNA1 0603BNA1 0803BNA1 1005CNA1 CVENT-2 Concentric Vent Kit (2â€) √ √ √ √ CVENT-3 Concentric Vent Kit (3â€) √ √ √ √ CFSB17 Downflow Sub-Base 17.5" √ √ √ --- CFSB21 Downflow Sub-Base 21" --- --- --- √ CFSB24 Downflow Sub-Base 24" --- --- --- --- RF000142 Drain Kit -Horizontal Left Vertical Flue √ √ √ √ EFR01 EFR02 --- --- --- --- 0170K00000S Flush Mount Vent Kit - 3" or 2" √ √ √ √ 0170K00001S Flush Mount Vent Kit - 2" √ √ √ √ AFE18-60A Fossil Fuel (Duel Fuel) Kit √ √ √ √ High-Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-2 High-Altitude LP Gas Kit TBD TBD TBD TBD LPLP03 Low LP Gas Pressure Switch √ √ √ √ LPM-08 LP Conversion Kits (Gas Valve) √ √ √ √ NOTE: 1Twinning kit is not required, but the furnace is capable of twinning. See details in the unit IO manual. 10 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com 11 Notes Our continuing commitment to quality products may mean a change in specifications without notice. © 2020 • Houston, Texas 12 www.daikincomfort.com SS-DC96VE SS-DC96VE www.daikincomfort.com PB ! "#$% &'()*+ ,-$.% /)012314!*5&)(6 ,-$.,7788 9*: ,-$.;<;=;> ('2'?)@2ABC <".$ D". EECE E F- G)0123142*5&)(6HG)0123142*5&)(6I1'? =$""JK"L *G051**M)@&)(6N3+(51*O)&2(*O P-Q". I =RQS %QT"J="8 <".8Q$". U$$Q.$V"Q W<"7 W88Q7 FX8 Y C S" =Q8 Z/ ,88[.7" ?*+*@)55O0)@ " /5+1*0: \\+*@@*650*@1+)G&)'(]O(*+5?* ]O(*+/2'(* ^'()(6 b ` ECE C_CY CY cd a <".$"8 '(&+51&'+/+)?5+e '(&51&/2'(*\\+*@@ '(&+51&'+eG*)1*(@* )1*(@*: 9*(3*A ]a ] /)012314!*5&)(6f*NN50g*+& EhE hE C ] E_C : ] ] 9*(3*A ]a ] '(@&+31&)'( /)012314!*5&)(6f*NN50g*+& EhE hE C / !!C Y : ] ] '(&+51&'+ S8 c***@1+)G&)'('&*@?'3(& !" # $%&'( )*+,-,, .&&'/01231&&145 6 76 8!8! 9:;<=;>?@ABC;D E'FG1H&5 6 #6 #"## 8!8! 6I#JJ 8 K K LM&5&'H2NHOP'('H/1 ),-,, QR(%'212SN(15 6 T 8!8! UVWUXXYZXY[\]^__<;`aD;b>c_=d 8!8! UVWUXX\ZXY[\]e_A`fc_=d